Viscosity measurement across demanding applications

UFIT viscosity systems are used wherever precise and stable viscosity control is critical for product quality, safety, and process efficiency.


Typical customer groups include:

  • Polymer producers – monitoring viscosity to control molecular weight and batch consistency.




Customers industries in details
Application:
Determination of intrinsic viscosity (IV) to control molecular weight of polymers.
Implementation:
  • Sample is dissolved according to standard methods
    • PET (Polyethylene terephthalate)
    • → Phenol / 1,2-dichlorobenzene
    • Polyamide (PA, Nylon)
    • → Sulfuric acid or formic acid
    • PVC (Polyvinyl chloride)
      → Cyclohexanone or THF
    • Polystyrene (PS)
      → Toluene
  • Measurement with capillary viscometer at precisely (+-0.01°C) controlled temperature (e.g. 25 °C or 135 °C)
  • Automatic calculation of IV and correlation to molecular weight
Customer Benefit:
  • Consistent material properties
  • Reliable batch release
  • Early detection of polymer degradation

In polymer, viscosity is a key indicator of molecular weight, degree of crosslinking, and consistency between batches. Typical applications include production control for polymer solutions and incoming goods inspection of raw materials.

UFIT viscometers are used in laboratory and QC environments to characterize polymer solutions with high accuracy and repeatability, but also in research & development to check new developped products in their characteristics


Our products for laboratory and quality control:


Capillary Viscometers (UFIT VA series), the heart of the measurement and

UFIT Viscosity Systems UVS, our measurement systems having chemically resistant components and a high precise temperature bath are available for aggressive solvents and elevated temperatures.

🛢️ Lubricants & Mineral Oils
Application:
Precise determination of kinematic viscosity according to standards (e.g. ASTM D445).
Implementation:
  • Measurement at multiple temperatures (e.g. 40 °C and 100 °C)
  • Use of calibrated capillaries with automated timing
  • Integration into LIMS systems
Customer Benefit:
  • Compliance with international standards and OEM specifications
  • Optimized lubrication performance and energy efficiency
  • Full traceability and audit readiness

For lubricants, hydraulic oils, and engine oils, viscosity directly determines film strength, pumpability, and energy efficiency. Producers must ensure tight viscosity tolerances across different temperatures to meet international standards and OEM specifications.

UFIT systems support laboratory measurements of base oils, additive packages, and finished lubricants across a defined temperature range.

Recommended products: Capillary Viscometers for precise laboratory characterization

Optional temperature control modules and calibration standard kits help ensure traceable, long-term stable results.

Application:
Determination of intrinsic viscosity → correlation with molecular weight and product quality
1. Polymer-Based APIs and Excipients
  • Gelatin (e.g. for capsules)
  • Cellulose and derivatives
    • HPMC (Hydroxypropyl methylcellulose)
    • MC (Methylcellulose)
    • CMC (Carboxymethylcellulose)
  • PVP (Polyvinylpyrrolidone)
  • PEG (Polyethylene glycol)
  • PLA / PLGA (biodegradable drug delivery polymers)
  • Hyaluronic acid (HA) (non-crosslinked, in dilute solution)

2. API Solutions
  • Low-viscosity active pharmaceutical ingredient (API) solutions
  • Stability studies (viscosity changes over time)
  • Purity and batch consistency control

3. Syrups and Oral Solutions
  • Cough syrups
  • Sugar-based formulations (e.g. sucrose solutions)
  • Liquid oral dosage forms
👉 Important for:
  • Flow behavior
  • Dosing accuracy
  • Batch-to-batch consistency

4. Parenteral Solutions
  • Infusion solutions (e.g. glucose, saline)
  • Injectable low-viscosity formulations
👉 Control of:
  • Injection behavior
  • Product uniformity

5. Solvents and Pharmaceutical Raw Materials
  • Ethanol, isopropanol
  • Glycerol (in diluted form)
  • Propylene glycol
  • Purified water / buffer solutions
👉 Used for reference measurements and quality control

6. Coating and Processing Solutions
  • Film-coating solutions
  • Polymer-based tablet coatings
  • Binder solutions
Application:
Determination of the degree of polymerization (DP) of cellulose via solution viscosity.
Implementation:
  • Dissolution of cellulose in CED solution
  • Measurement with capillary viscometer according to ISO 5351
  • Calculation of molecular weight / DP
Customer Benefit:
  • Control of pulp quality
  • Optimization of pulping and bleaching processes
  • Assurance of paper strength properties


Designed for uptime and lifecycle stability

UFIT systems are built for continuous use in industrial environments and for long service lives in laboratories.

  • High availability – Robust mechanical design, proven components, and conservative operating points help to minimize unplanned downtime.
  • Lifespan and serviceability – The modular concept allows worn parts or modules to be replaced without changing the complete system.
  • Stable measurement performance – Careful selection of capillaries, sensors, and temperature control ensures stable calibration over time.
  • Support over the system lifecycle – UFIT supports customers with commissioning, training, maintenance, and upgrades as process requirements evolve.

Many systems operate reliably for many years with only routine maintenance and periodic verification.

Tell us about your application








I agree that UFIT GmbH may use my data to process my request. Further details are described in the Privacy Policy.
Direct contact

If required, we can provide contact persons or more detailed reference information for projects in your industry, subject to confidentiality agreements.

You can also reach us directly:

Email: sales@ufit.de
Phone: +49 155 69 47 57 25

We will clarify which media, temperature and relevant norms are relevant for you and provide matching reference examples.